Summary
Home ] General Information ] AIT Batam Activities ] Lead Free Lead Finish ] Pre Plated Frame ] Joint Evaluation ] [ Summary ] Evaluation Report ] Revision History ] FAQ & References ] Appendix ]

 

Summary of Pure Tin Plating Evaluation
Summary of Pure Tin Plating Evaluation
   
Whisker Mitigation Strategy
  • Select Matte Tin, low stress chemistry
  • Tight control on bath concentrations
  • Maintain plating thickness average of 400 – 450 micro inches (10 – 11 microns)
  • Recommended to apply Post Plate Bake at 150oC for 1 hour (optional)

Note: No chemical supplier guarantees that the process will be free from whisker.

Lead Contamination Preventive Action
Ref : Customer requirement on maximum lead content is 1000 ppm

Preventive Action
  • Use high purity solder anodes (99.99% Sn)
  • Regular bath maintenance to settle down lead
  • Use dedicated chemical handling apparatus for pure tin process

 

Wetting Curve of Pure Tin: Solderability Test Condition:
Pure Tin Wetting Curve
  • Solder: Sn-3.8Ag-0.7Cu
  • Flux: Water Soluble
  • Temperature: 245 +/- 5 oC
  • Tested material: 14/16L PDIP
  • Sample size: 11 unit

 

  
Result of Solderability Test using Lead-Free solder paste
Solder paste : OMG Microbond NL1D-P3-NCD8001-0
Solder paste type : 96Sn-3.5Ag-0.5Cu
Lead type : 48L TSSOP / 44L PLCC
Type of oven : Vitronics IR Reflow (lab scale)
IR Reflow peak temperature : 260 oC
IR Reflow speed : 250 mm/min
Test Result : All parts pass the solderability test as per EIA/JESD22-B102-C and J-STD-002
  
IR Reflow Profile
IR Reflow Profile
  
Evaluated Package and Lead Type
Evaluated Package and Lead Type
  
Whisker Evaluation Result Summary
Whisker Eval 1
Whisker Eval 2
Whisker Eval 3
  
Summary of Pure Tin Evaluation at Customer M
Test Vehicle: 64L LQFP
Pure Tin Evaluation at Customer M
click here for solderability evaluation report
   
Pure Tin Pre-qualification result for Customer I
Pure Tin Pre Qualification for Customer I
Impurities Composition
Impurities Composition
 

Conclusion: 
AIT's lead-free plating has passed all qualification requirements.

 
 

© PT. AIT Batam, 2000-2004

Rev 38, Aug 2004